Use and Care Manual
Fig. 7.
6).
is tilted downwards to the outside, about 3° to 4°, as shown in
6
Installation Instructions
3) Completing the Installation (cont)
• Carefully place the air conditioner into the window with the “L” shaped
mounting bracket (on top) positioned in front of the upper window sash.
The bottom of the cabinet should be positioned on the “recessed” portion
of the window frame. Pull the window down until it rests just behind the
front flange of the (top) “L” shaped mounting bracket (See Fig. 5).
• Expand the shutter frames (fully) on each side and secure the top of the
frames to the window sash using one 1/2” screw on each side and one in
the “L” shaped mounting bracket (Fig. 5).
• Secure the shutter clamp on each side of the lower part of the shutter and
secure to the window sill using one 1/2” screw on each side (Fig. 5).
• Place the second foam sealing strip to fit the opening between the inside
and outside windows, then attach the safety lock to the outside window
frame using
one 1/2” screw (See Fig.
Fig. 7
Measure the tilt angle from the cabinet’s edge
WINDOW
: approximately 3/4” to 1”
PLEASE NOTE: Window applications come in a variety of different styles. Therefore, it may
After proper installation,
condensed water should not drain from the overflow drain hole during
normal use. If you notice water leaking out , check the angle of tilt, and make any necessary
adjustments. However, on a very humid day, water leakage can occur – this is normal.
Measure the tilt angle from the cabinet’s edge. The distance H should be approximately
3/4” to 1” for DAC060EB2GDB.
Window sash
“L” Shaped
Mounting
Bracket
Shutter clamps
1/2” screws
Fig. 5
Safety Lock
1/2” screw
Foam
(adhesive)
Seal
Fig. 6
be necessary to modify or improvise your particular installation.
Check that the air conditioner