Installation manual

Danaher Motion Kollmorgen System Description
SERVOSTAR
®
S and SERVOSTAR
®
CD Series 84
Fatal and non-fatal error coding with text explanation to the host (ERR,
FLTHIST, FLTCLR). A run-time counter (TRUN) that records the time the
error occurred is also provided.
Configurable motor thermal protection that accepts various thermostat types
(THERM, THERMODE, THERMTYPE, THERMTIME).
Configurable drive thermal protection through the fold-back feature (FOLD,
FOLDMODE). It sets the maximum time limit the drive can provide peak
current (2:1 for Sx or 3:1 for Cx) to the motor.
Configurable motor thermal protection through the motor fold-back feature
(MFOLD, MFOLDD, MFOLDDIS, MFOLDR, MFOLDT). It sets the
maximum time limit the drive can provide continuous current to the motor.
Hardware position limit switch detection (CCWLIM, CWLIM, LIMDIS,
IN1, IN2, IN3, IN1MODE, IN2MODE, IN3MODE).
Configurable software position limits (PLIM, PMAX, PMIN, PEMAX).
Configurable fault relay output (RELAY, RELAYMODE, DISTIME,
IN1MODE, IN2MODE, IN3MODE).
Active disable feature (ACKFAULT) that allows you to determine how the
system should react at the occurrence of a fault. The system can
immediately disable, where the motor will coast to a stop, or it can be
programmed to a controlled decelerated stop (DECSTOP, DISSPEED,
DISTIME, STOPMODE, ISTOP).
Active enable indicator through the Status Display decimal (ACTIVE,
DRIVEOK, SWEN, READY, REMOTE, DIPEN).
General
Many enabling and disabling features (K, S, STOP, REMOTE, EN, DIS).
Flash firmware memory for easy field upgrade installation.
Danaher Motion Kollmorgen’s patented “Torque Angle Control” for buried
magnet motor designs (MTANGLC, MTANGLP, MTANGLF, MTANGLH
- defined as speed and torque optimization through commutation angle
advancing of the drive’s output current waveform with respect to the
motor's back EMF waveform.
Firmware and serial number information (VER, SERIALNO, MOTOR) via
terminal.