Installation manual

Danaher Motion Kollmorgen System Communication
SERVOSTAR
®
S and SERVOSTAR
®
CD Series 52
Should you de-activate this screen, it can be reactivated by going to the
Main MOTIONLINK screen, pulling down the Configuration menu,
and selecting the New Drive (123) option.
Startup Wizard
Setting Drive Variable Parameters: Click the Drive button. This screen
allows you to select a BUS value that corresponds to the incoming line
voltage. This selection actually determines the setting of the variable
VBUS. Also included is a realtime monitoring of the DIP switch on top of
the drive so you can verify the proper setting for the drive address, baud
rate, and various other parameters. Click Exit to return to the Startup screen.
Setting Motor Variable Parameters: Click the Motor button. This screen
allows you to access the MOTIONLINK motor database. Select a motor
family and then a model within that family. Information will appear in the
blank parameter fields on the right. Click on the “To Drive” button beneath
the fields to send the variable parameters to the drive. Click “Exit” to return
to the MOTIONLINK Start-Up Wizard.
If you have a configured drive, a “From Drive” button is provided to
retrieve the motor data already in the drive. Retrieving this data does
not erase it from the drive.