Installation manual
Danaher Motion Kollmorgen Wiring
SERVOSTAR
®
S and SERVOSTAR
®
CD Series 29
BUS Module Regen Information
Product Model PA-LM PA08 PA14 PA28
Peak current (amps) N/A 30 32
Resistance (ohms) N/A 7.5 12.5
Watts N/A 40 40
Internal Shunt
Regulator
Fuse Rating (amps)(internal) N/A 7 8
Peak current (amps) N/A 40 45
Minimum resistance (ohms) N/A 4.25 8.8
External Shunt
Regulator*
Watts N/A 300 400
Capacitance (Farads) 0.00165 0.00165 0.00198
BUS Voltage (nominal) (VDC) 325
V
HYS
(Regen turn-off) (VDC) 370
Application
Information
V
MAX
(Regen turn-on) (VDC) 390
Resistance (ohms) 12.5 12.5
Internal Regen
Power Rating (Watts) 40 40
ER-30
a a
External Regen
Kits
ERH-40
a a
* For guidance on application sizing of Regen Kits, see the SERVOSTAR S-
and
CD-Series Regeneration Requirements Application Note.
Product Model PA50 PA75 PA85
Peak current (amps) N/A N/A N/A
Resistance (ohms) N/A N/A N/A
Watts N/A N/A N/A
Internal Shunt
Regulator
Fuse Rating (amps)(internal) N/A N/A N/A
Peak current (amps) 100 200 200
Minimum resistance (ohms) 4.5 2.2 2.2
External Shunt
Regulator*
Watts 1000 2000 2000
Capacitance (Farads) 0.00392 0.00504 0.00504
BUS Voltage (nominal) (VDC) 325
V
HYS
(Regen turn-off) (VDC) 370
Application
Information
V
MAX
(Regen turn-on) (VDC) 390
ER-20
a a a
ER-21
a a a
ER-22
a a
External Regen Kits
ER-23
a a
* For guidance on application sizing of Regen Kits, see the SERVOSTAR S-
and
CD-Series Regeneration Requirements Application Note.