Installation manual

Danaher Motion Kollmorgen Wiring
SERVOSTAR
®
S and SERVOSTAR
®
CD Series 28
Product Model PA50 PA75 PA85
Power
(Source)
Max. # of Drives Sourced Refer to the SERVOSTAR Bus Module Sizing
Application Note.
115 VAC Turn-Off Level (powerup)
115 VAC Turn-On Level (normal)
230 VAC Turn-Off Level (powerup) 125 125 125
230 VAC Turn-On Level (normal) 35 35 35
Max. Surge Current (amps)
during power application
40 40 40
SoftStart
Max. Charge Time (sec) 0.5 0.75 0.85
Fault Contact Rating
1 Amp max. at 115 VAC (±15%)
Fault Contact Closing Period (ms) 250
Protection
Functions
OverTemperature trip
90°C (194°F)
Internal heat dissipation 200 275 294
Operation temperature (°C/°F) 5°/41 to 45/113
Storage temperature (°C/°F)
0/32 to 70/158
Ambient humidity (%) 10 to 90
Atmosphere without corrosive gasses or dust
Altitude Derate 5% per 1000 ft. above 3300 ft.
Environment
Vibration (g) 0.5
Cx Regen Information
Product Model Cx03 Cx06 Cx10
Peak current (amps) 20
Minimum resistance (ohms) 20
External Shunt Regulator
Watts 200
Capacitance (Farads) 0.00082 0.00164
BUS Voltage (nominal) (VDC) 325
V
HYS
(Regen circuit turn-off) (VDC) 370
Application Information
V
MAX
(Regen circuit turn-on) (VDC) 390
External Regen Kits ERH-26
a a a
*For guidance on application sizing of Regen Kits, see the SERVOSTAR S- and CD-
Series Regeneration Requirements Application Note.