Installation manual
Danaher Motion Kollmorgen Wiring
SERVOSTAR
®
S and SERVOSTAR
®
CD Series 27
Product Model PA-LM PA08 PA14 PA28
115 VAC Turn-Off Level
(power-up)
70 70
115 VAC Turn-On Level
(normal)
50 50
230 VAC Turn-Off Level
(power-up)
70 125
230 VAC Turn-On Level
(normal)
50
112
Max. Surge Current (amps)
during power application
30 20 50
Max. Charge Time (sec)
0.75 0.25
Fault Contact Rating (±15%)
1 Amp max. at 115 VAC
Fault Contact Closing Period
(mSec)
250 ms
Protection
Functions
OverTemperature trip
N/A
90°C (194°F)
Internal heat dissipation 7 45 70 130
Operating temp. (°C/°F) 5°/41 to 45/113
Storage temp. (°C/°F)
0/32 to 70/158
Ambient humidity (%) 10 to 90
Atmosphere without corrosive gasses or dust
Altitude Derate 5% per 1000 ft. above 3300 ft.
Environment
Vibration (g) 0.5
Product Model PA50 PA75 PA85
Voltage (VAC
L-L
) Nominal ±10%
208-240
115VAC 1φ and 3φ
N/A
230VAC 1φ and 3φ
3
Line Frequency 47-63
KVA at 230 VAC
20 (3φ)
30 (3φ)
34 (3φ)
230 VAC Continuous Current
(amps)
50 (3φ)
75 (3φ)
85 (3φ)
230 VAC Peak Current (amps) for
2s /50ms (normal operation)
3φ: 75/100
3φ: 115/150
3φ: 130/170
Main Input
Power
Line Fuses (FRN, LPN, or equiv.) 60 80 100
DC BUS Voltage (Nominal) 310 310 310
Main Output
Power
(Source)
kW at 230 VAC Line Input
15.5 (3φ)
23.3 (3φ)
26.4 (3φ)
Voltage (VAC) Nominal ±10%
208 to 240
Max. Current 1φ (amps)
1 1 1
Line Frequency 47-63 47-63 47-63
Logic Input
Power
Internal Fuse (amps) (internal) 2.5 2.5 2.5
+8VDC Supply Voltage (VDC) +7.25 to +8.5
+8 VDC Supply Current (amps) 4.4 4.4 4.4
15 V Supply Voltage (±VDC) 14.25 to 16
15 V Supply Current (amps) 2.4 2.4 2.4
Logic Output
Internal Fuses (A) (±15V/+8 V)
3.5/7 3.5/7 3.5/7