Installation manual
Danaher Motion Kollmorgen Wiring
SERVOSTAR
®
S and SERVOSTAR
®
CD Series 26
BUS Module Electrical Specifications
Product Model PA-LM PA08 PA14 PA28
Voltage (VAC
L-L
) Nominal
±10%
110-240 110-120 208-240
115VAC 1φ and 3φ
1/3 1/3 N/A
230VAC 1φ and 3φ
1/3 1/3
Line Frequency 47-63
KVA at 115 VAC
0.92 (1φ)
1.6 (3φ)
1.6 (1φ)
2.8 (3φ)
KVA at 230 VAC
1.8 (1φ)
3.2 (3φ)
3.2 (1φ)
11.2 (3φ)
115 VAC Continuous Current
(amps)
8 (1φ)
8 (3φ)
14 (1φ)
14 (3φ)
230 VAC Continuous Current
(amps)
8 (1φ)
8 (3φ)
14 (1φ)
28 (3φ)
115 VAC Peak Current
(amps) for 2sec/50 ms
12 (1φ)
16 (3φ)
1φ:21/28
3φ:28/42
230 VAC Peak Current
(amps) for 2sec/50msec
during normal operation
1φ: 12/16
3φ: 16/24
1φ: 21/28
3φ: 56/84
Main Input
Power
Line Fuses (FRN, LPN, or
equivalent)
10 20 35
DC BUS Voltage (Nominal) 140/310 140 310
kW at 115 VAC Line Input
0.67 (1φ)
1.24 (3φ)
1.1 (1φ)
2.1 (3φ)
Main Output
Power
(Source)
kW at 230 VAC Line Input
1.3 (1φ)
2.48 (3φ)
2.0 (1φ)
8.7 (3φ)
Voltage (VAC) Nominal ±10%
110 - 120 208 - 240
Max. Current 1φ (amps)
1 1 1 1
Line Frequency 47-63 47-63 47-63 47-63
Logic Input
Power
Internal Fuse (amps)
(internal)
2.5 2.5 2.5 2.5
+8VDC Supply Voltage +7.25 VDC to +8.5 VDC
+8 VDC Supply Current
(amps)
2.2 2.2 2.2 4.4
15 V Supply Voltage (±VDC) 14.25 to 16
15 V Supply Current (amps) 0.8 0.8 0.8 2.4
Internal Fuses (amps)
(±15V/+8 V)
1.5/3.5 1.5/3.5 3.5/7 3.5/7
Logic Output
Power
(Source)
Max. # of Drives Sourced Refer to the SERVOSTAR Bus Module Sizing
Application Note.