Installation manual

Danaher Motion Kollmorgen Wiring
SERVOSTAR
®
S and SERVOSTAR
®
CD Series 25
Product Model Sx30 Sx55 Sx85
BUS (VDC) 260 to 360 Main Input
(BUS+ / BUS-)
Rated Power at DC (kW) 13.33 24.45 37.20
Continuous Power (KVA) at 165 VDC
BUS Input (45°C (113°F) Ambient)
N/A N/A N/A
Continuous Power (KVA) at 325 VDC
BUS Input (45°C (113°F) Ambient)
11 20 33.8
Continuous Current (Arms) 30 55 85
Peak Current (Arms) for 500mSec 60 110 170
Peak Current (Arms) for 2Sec 60 110 170
PWM Frequency (kHz) 8
PWM Motor Current Ripple (kHz) 16
Rated Main Output
(MA, MB, MC)
Form Factor (rms/avg)
1.01
+8 VDC Supply Voltage 7.3 to 8.5
±15 VDC Supply Voltage
14.3 to 15.5
+8 VDC Supply Current (amps) 1.1
Control Input
(Sinking)
±15 VDC Supply Current (amps)
0.47 0.66 0.87
UnderVoltage Trip (on power-up) (VDC) 255
UnderVoltage Trip (nominal) (VDC) 125
OverVoltage Trip (VDC) 430
Protective
Functions
OverTemperature Trip (°C)
90
Internal heat dissipation in 45°C (113°F)
ambient at continuous current (W)
(not including regen)
254 465 675
Operation temperature (°C/°F)
0/32 to 45/113
Storage temperature (°C/°F)
-20/-4 to 70/(158
Humidity (non-condensing) (%) 10 to 90
Atmosphere without corrosive gasses or dust
Altitude Derate 5% per 1000 f.t above 3300 ft.
Environment
Vibration (g) 0.5