Installation manual
Danaher Motion Kollmorgen Wiring
SERVOSTAR
®
S and SERVOSTAR
®
CD Series 24
Product Model Cx03* Cx06* Cx10
UnderVoltage Trip (nominal) 90 VDC
OverVoltage Trip 430 VDC
OverTemperature Trip
80°C (176°F)
Protective Functions
Internal heat dissipation (watts) 60 80 132
Operation temperature
5°C (41°F)to 45°C (113°F)
Storage temperature
0°C (32°F) to 70°C (158°F)
Ambient humidity 10% to 90%
Atmosphere without corrosive gasses or dust
Altitude Derate 5% per 1000 ft. (300m) above 3300
ft. (1000m)
Environment
Vibration 0.5 g
*NOTE: Model Numbers Cx0x200 are single phase only!
Sx Electrical Specifications
Product Model Sx03 Sx06 Sx10 Sx20
BUS (VDC) 125 to 360 260 to 360 Main Input
(BUS+ / BUS-)
Rated Power at DC (kW) 0.63-1.4 1.26-2.79
1.96-4.34 8.68
Continuous Power (KVA) at 165 VDC
BUS Input (45°C (113°F) Ambient)
0.55 1.1 1.6 N/A
Continuous Power (KVA) at 325 VDC
BUS Input (45°C (113°F) Ambient)
1.1 2.2 3.6 7.2
Continuous Current (Arms) 3 6 10 20
Peak Current (Arms) for 500mSec 6 12 20 40
Peak Current (Arms) for 2Sec 6 12 20 40
PWM Frequency (kHz) 16 8
PWM Motor Current Ripple (kHz) 32 16
Rated Main Output
(MA, MB, MC)
Form Factor (rms/avg)
≤1.01
+8 VDC Supply Voltage 7.3 to 8.5
±15 VDC Supply Voltage
14.3 to 15.5
+8 VDC Supply Current (amps) 1.1
Control Input
(Sinking)
±15 VDC Supply Current (amps)
0.37 0.38 0.5
UnderVoltage Trip (on power-up)
(VDC)
90 255
UnderVoltage Trip (nominal) (VDC) 90 125
OverVoltage Trip (VDC) 430
Protective
Functions
OverTemperature Trip (°C)
118 90
Internal heat dissipation in 45°C
(113°F)
ambient at continuous current
(W) (not including regen)
37 84 120 240
Operation temperature (°C/°F)
0/32 to 45/113
Storage temperature (°C/°F)
-20/-4 to 70/(158
Humidity (non-condensing) (%) 10 to 90
Atmosphere without corrosive gasses or dust
Altitude Derate 5% per 1000 f.t above 3300 ft.
Environment
Vibration (g) 0.5