Installation manual
Danaher Motion Kollmorgen Wiring
SERVOSTAR
®
S and SERVOSTAR
®
CD Series 17
• Filter should be mounted as close as possible to BUS Module. If separation
exceeds 30cm. (1 ft.), flat cable (braid) is used for the high frequency
connection between filter and BUS Module.
• When mounting the filter to the panel, remove any paint or material
covering. Use an unpainted metallic back panel, if possible.
• Filters are provided with an earth connection. All ground connections are
tied to ground.
• Filters can produce high leakage currents. Filters must be earthed before
connecting the supply!
• Filters should not be touched for a period of 10 seconds after removing the
supply.
Recommended Line Filters
BUS Module Model # Recommended EMI Line Filter Danaher Motion Kollmorgen Part #
PA08 (Single phase) Filter Concepts SF10 n/a
PA08 (3 phase) Schaffner FN258-30/07 A-96776-003
PA28 Schaffner FN258-30/07 A-96776-003
PA50 Schaffner FN258-55/07 A-96776-005
PA75 Schaffner FN258-75/34 A-96777-001
PA85 Schaffner FN258-100/35 A-96777-002
PALM Corcom F7202A A-97181
PA14 (single phase) Filter Concepts SF15 n/a
PA14 (3 phase) Schaffner FN258-30/07 A-96776-003
Cx03 Filter Concepts SF7
Schaffner FN258-7/07
n/a
A-96776-001
Cx06 Filter Concepts SF15
Schaffner FN258-16/07
n/a
A-96776-002
Cx10 Schaffner FN258-16/07 A-96776-002
The filters called out in the table above are used on a one-to-one
corresponedence with the drive. If drives are paralled off one filter, it
needs to be sized. Drives can be ganged off one EMI filter as shown in
the Filter and Bonding Diagrams.