Installation manual
Danaher Motion Kollmorgen Wiring
SERVOSTAR
®
S and SERVOSTAR
®
CD Series 15
The next two figures represent a side and top view of the SK device that clamps
down on the shield of the cable. The Phoenix SK device is excellent for
providing a low impedance path between cable shield and the back panel.
Cable shield compressed on
copper bus bar
Thumb screw to tighten down shield to
bus bar
Copper bus bar
SK(8, 14, 20,
- Shielded terminal block
Phoenix Contact - Side View
SK
x
– for
connecting
shield to bus
bar
Copper Bus Bar
Support for bus bar
High frequency ground
connection to back panel from
bus bar
Phoenix Contact -Top View