Installation manual

SERCOS Interface Setup 08/04 Danaher Motion Kollmorgen
60 M-SS-001-01 Rev. T SERVOSTAR S Installation
6.4.2.4. Equation Notes
1. Cnts = the number of encoder (or resolver equivalent) counts
per revolution.
Where: Encoder counts = Encoder lines * 4.
Resolver counts = 2^16 * MResPoles/2
2. CUCT = The control unit cycle time (IDN 1) in ms.
3. The units "CUCT/ms" is the number of CUCT periods per ms.
For example, a 2 ms CUCT has 1/2 a CUCT per 1 ms.
4. Remember the following when monitoring a SERCOS interface
drive through the serial port:
The SERCOS interface address is also the serial
MultiDrop address
SERCOS interface operation changes the UNITS variable
to internal units
The SERCOS interface version of the SERVO
STAR is not
enabled automatically on power-up, even with the drive
address set to 0.