Installation manual

Danaher Motion Kollmorgen 08/04 System Communication
SERVOSTAR S Installation M-SS-001-01 Rev. T 47
5.2.3 SETTING DRIVE ADDRESS
The following table shows the MultiDrop DIP switch address settings
(Note: OFF = 0)
Drive Address Switch 5 Switch 4 Switch3 Switch 2 Switch 1
* 0 (single unit
addressing
only)
0 0 0 0 0
1 0 0 0 0 1
2 0 0 0 1 0
3 0 0 0 1 1
4 0 0 1 0 0
5 0 0 1 0 1
6 0 0 1 1 0
7 0 0 1 1 1
8 0 1 0 0 0
9 0 1 0 0 1
A 0 1 0 1 0
B 0 1 0 1 1
C 0 1 1 0 0
D 0 1 1 0 1
E 0 1 1 1 0
F 0 1 1 1 1
G 1 0 0 0 0
H 1 0 0 0 1
I 1 0 0 1 0
J 1 0 0 1 1
K 1 0 1 0 0
L 1 0 1 0 1
M 1 0 1 1 0
N 1 0 1 1 1
O 1 1 0 0 0
P 1 1 0 0 1
Q 1 1 0 1 0
R 1 1 0 1 1
S 1 1 1 0 0
T 1 1 1 0 1
U 1 1 1 1 0
V 1 1 1 1 1
** Note: When the switch setting is set for binary 0, the drive assumes a single-line
serial configuration.