Installation manual

Danaher Motion Kollmorgen 08/04 Wiring
SERVOSTAR S Installation M-SS-001-01 Rev. T 39
4.9.5 SINE ENCODER FEEDBACK DIAGRAM
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
HALL 3 A
HALL 3 B
HALL 2 A (D)*
HALL 2 B (D)*
HALL 1 A (C)*
HALL 1 B (C)*
COMMON
+5 V
COMMON
+5 V
CH B
CH B
CH A
CH A
MARKER
MARKER
MOTOR THERMOSTAT MUST
BE CLOSED TO RUN
(SEE BELOW)
ENCODER POWER SUPPLY
(SEE NOTE 1)
OPTIONAL
HALL
CHANNEL
INPUTS
DIFFERENTIAL
LINE DRIVES
LINE DRIVERS
CONNECTING HALLS WITH
OPEN COLLECTOR
ENCODER
HALL n B
HALL n A
HALL n A
HALL n B
PIN 18 (+5 V)
COMMON
COMMON
HALL n A
HALL n B
150
150
1k
ENCODER TYPES AND OPTIONS VARY GREATLY.
PROVISIONS FOR OPERATING WITHOUT HALL
CHANNELS USING SOFTWARE SWITCHES ARE AVAILABLE.
SERVOSTAR
SERVOSTAR
SERVOSTAR
INTERNAL
CIRCUITRY
HI (TRUE)
LO (COMPLEMENT)
MOTOR OVERLOAD PROTECTION
MOTORS MUST HAVE INTEGRAL THERMAL PROTECTION OR
EXTERNAL MOTOR OVERLOAD MUST BE USED.
THERMOSTAT SWITCH MAY SEE +12 VOLTS AND 20 ma.
ENCODER/SINE ENCODER VERSION
*INPUTS FOR SINE ENCODER THAT
HAVE C & D CHANNELS