Installation manual
Wiring 08/04 Danaher Motion Kollmorgen
32 M-SS-001-01 Rev. T SERVOSTAR S Installation
4.7.2 TOP VIEW
C7
C8
1
10
24V
C7: MultiDrop Communications
Type: 10 Pin (0.1 in x 0.1 in) female ribbon cable. Connector and cable
are included in the optional CK100 kit. This connector functions only
when using the R-S232 interface. It will NOT function using RS-485.
C8: Remote Encoder Input
Pin Function
1 A Input + (High)
2 A Input - (Low)
3 DC Common
4 B Input + (High)
5 B Input - (Low)
6 Shield Connection
7 Reserved
8 Index +
9 Index -
See Position Loop for features using this input