Installation manual

Danaher Motion Kollmorgen 08/04 Wiring
SERVOSTAR S Installation M-SS-001-01 Rev. T 27
4.6.1.2. PA50, 75, or 85 Wiring Diagram
CUSTOMER
SUPPLIED
FUSING
SYSTEM POWER
L1
L2
L3
FAULT CONTACTS
MOMENTARY
PUSHBUTTON
TO ENERGIZE
MAIN POWER.
E-STOP
+15 V
- 15 V
+ 8 V
DC COMMON
DC BUS OK
C7
1
2
3
4
1
2
C6
C8
1
2
3
FAULT CONTACT
LOGIC
OUTPUT
LA LB LC
BUS +
BUS -
(SEE NOTE 4)
(SEE NOTE 7)
(SEE NOTE 9)
(SEE NOTE 8)
(SEE NOTE 5)
MAIN POWER CONTACTOR
(SEE NOTE 11)
OVERLOAD RELAY
(SEE NOTE 3)
(SEE NOTE 1)
(SEE NOTE 13)
230 VAC LOGIC INPUT
NORMALLY OPEN
AUXILLIARY
POWER CONTACT
FROM
MAIN POWER
CONTACTOR
SHIELD TO
STAR POINT
(SEE NOTE 15)
DO NOT
GROUND
SHIELD
STAR
POINT
(SEE NOTE 14)
(SEE NOTE 14)
(SEE NOTE 10)
(SEE NOTE 16)
INPUT FILTER
INPUT
FILTER
EXTERNAL
REGEN
RESISTOR
BUS MODULE
PA 50/75/85
To Sx Drive
connector C5
To Sx Drive BUS +
To Sx Drive BUS -
4.6.2 BUS MODULE – PA-LM (MULTIPLE SX
UNITS
)
Some PA logic supplies can source up to four drives. Check the
bus module electrical specifications table for the maximum logic
source.
When mating multiple drives to one bus module, the wire gauge
must be sized with respect to the current rating of the bus module.
Terminal lug sizes between the bus module and the drive may
differ. Refer to the hardware specifications table for terminal sizes.
In some cases, the PA-LM can only source one drive. Check the
bus module electrical specifications table for the maximum logic
sources.
When connecting multiple drives to one bus module, split the drives
as evenly as possible on either side of the bus module.