Installation manual

Danaher Motion Kollmorgen 08/04 Wiring
SERVOSTAR S Installation M-SS-001-01 Rev. T 21
Product Model Sx30 Sx55 Sx85
UnderVoltage Trip (on power-up) (VDC) 255
UnderVoltage Trip (nominal) (VDC) 125
OverVoltage Trip (VDC) 430
Protective
Functions
OverTemperature Trip (°C)
90
Internal heat dissipation in 45° C (113° F)
ambient at continuous current (W)
(not including regen)
254 465 675
Operation temperature (°C/°F)
0/32 to 45/113
Storage temperature (°C/°F)
-20/-4 to 70/(158
Humidity (non-condensing) (%) 10 to 90
Atmosphere without corrosive gasses or dust
Altitude Derate 5% per 1000 ft above 3300 ft.
Environment
Vibration (g) 0.5
4.5.2 BUS MODULE SPECIFICATIONS
Product Model PA-LM PA08 PA14 PA28
Voltage (VAC
L-L
)
Nominal ±10%
110-240 110-120 208-240
115 VAC 1φ and 3φ
1/3 1/3 N/A
230 VAC 1φ and 3φ
1/3 1/3
Line Frequency 47-63
kVA at 115 VAC
0.92 (1φ)
1.6 (3φ)
1.6 (1φ)
2.8 (3φ)
kVA at 230 VAC
1.8 (1φ)
3.2 (3φ)
3.2 (1φ)
11.2 (3φ)
115 VAC Continuous Current
(amps)
8 (1φ)
8 (3φ)
14 (1φ)
14 (3φ)
230 VAC Continuous Current
(amps)
8 (1φ)
8 (3φ)
14 (1φ)
28 (3φ)
115 VAC Peak Current
(amps) for 2 sec/50 ms
12 (1φ)
16 (3φ)
1φ:21/28
3φ:28/42
230 VAC Peak Current
(amps) for 2 sec/50 ms during
normal operation
1φ: 12/16
3φ: 16/24
1φ: 21/28
3φ: 56/84
Main Input
Power
Line Fuses (FRN, LPN, or
equivalent)
10 20 35
DC BUS Voltage (Nominal) 140/310 140 310
kW at 115 VAC Line Input
0.67 (1φ)
1.24 (3φ)
1.1 (1φ)
2.1 (3φ)
Main Output
Power
(Source)
kW at 230 VAC Line Input
1.3 (1φ)
2.48 (3φ)
2.0 (1φ)
8.7 (3φ)
Voltage (VAC) Nominal ±10%
110 - 120 208 - 240
Max. Current 1φ (amps)
1 1 1 1
Line Frequency 47-63 47-63 47-63 47-63
Logic Input
Power
Internal Fuse (amps)
(internal)
2.5 2.5 2.5 2.5
+8 VDC Supply Voltage +7.25 VDC to +8.5 VDC
+8 VDC Supply Current
(amps)
2.2 2.2 2.2 4.4
15 V Supply Voltage (±VDC) 14.25 to 16
Logic Output
Power
(Source)
15 V Supply Current (amps) 0.8 0.8 0.8 2.4