Product manual

Danaher Motion 05/2008 Basic Configuration
S200-VTS Product Manual 67
7.1.2 S1 - Rotary Setup Switch
Switch S1 is a 10-position rotary switch. The function of switch S1 depends on the feedback
mode in which the drive is configured.
7.1.2.1 S1 Function with SFD Feedback
When using the Smart Feedback Device (SFD), S1 sets the emulated encoder line count.
S1
Position
Emulated Encoder
Lines/Revolution
S1 Position
Emulated Encoder
Lines/Revolution
0
User settable
1
(factory default = 500)
5 2048
1 512 6 4096
2 1000 7 5000
3 1024 8 8192
4 2000 9 10000
1
S1 position 0 allows setting the non-volatile line count via the drive
parameter EncOut to any of the following values:
128, 512, 1024, 2048, 4096, 8192, 16384, 32768
125, 500, 1000, 2000, 2500, 5000, 10000, 20000
The value written replaces the factory default value listed in position 0 of
the table.
NOTE
The emulated encoder output is only available when using
SFD feedback to the base unit or a high-resolution feedback
device connected to the option card.