Product manual

Wiring the Drive 05/2008 Danaher Motion
50 S200-VTS Product Manual
External
4 - 30 VDC
Pow er Supply
Sinking Logic Output
from Field Device
J4-1
DINP COM
J4-2, 3, 4, 5
DINP1-4
DC
+
-
4.32 k
4.64 k
.
Sourcing Logic
For compatibility with sourcing outputs, the DINP COM
terminal is connected to the negative terminal of the
power source (4.0 to 30 VDC). The input (DINP1-4) is
connected to the sourcing logic output on the field device
as shown in the diagram below.
J4-1
DINP COM
J4-2, 3, 4, 5
Sourcing Logic
Output from Field
Dev ic e
External
4 - 30 VDC
Pow er Supply
DC
+
-
4.32 k
4.64 k
DINP1- 4
.
TTL and CMOS
Drivers
The following are examples of driving with TTL or CMOS
output devices.
+5 VDC
SINKING TTL or CMOS
4.32 k
4.64 k
+5 VDC
SOURCING CMOS
4.32 k
4.64 k