Product manual
Danaher Motion 05/2008 Wiring the Drive
S200-VTS Product Manual 45
6.5 J2 – Motor Power Connector
On smaller drives with Drive Ipeak 18 Arms or less J2 is a 4 pin pluggable connector. On
larger drives the motor power connection is made on fixed terminal block TB1 and needs no
mating connector.
1
4
(J2 Connector view from front of
drive).
Pin Description
J2-1
S200 AC Input Drives: PE (Physical Earth)
S200 DC Input Drives: BUS/CTRL GND
J2-2
Motor Phase W
J2-3
Motor Phase V
J2-4
Motor Phase U
Mating Connector Information
Screw Terminal Connector
12 – 24 AWG Wire Range, Phoenix MSTB2,5/4-STF-5,08-BK
OR
Spring Cage Clamp Connector
12 – 24 AWG Wire Range, Phoenix FKC 2,5/4-SFT-5,08-BK
OR
Crimp Connector
Crimp Shell
14-20 AWG Wire Range, Phoenix MSTBC 2,
5/4-STZF-5,08-BK
Crimp Contact
14-16 AWG Wire Range, Phoenix MSTBC-MT 1,5-2,5
Crimp Contact
18-20 AWG Wire Range, Phoenix MSTBC-MT 0,5-1,0
Refer to www.phoenixcon.com.
J2-1 or TB1-1
PE
Motor Case
Ground
On S200 AC Input Drives this point is connected to
Chassis Ground.
On S200 DC Input Drives this point is connected to
BUS/CTRL GND.
In either case this termination provides a convenient
point for the motor ground connection and motor
power wire shield.
Local electrical code may require using the Earth
Ground Chassis stud for this function.
J2-2, 3, 4
or TB1-2,3,4
Motor Phases
These three terminals provide the 3-phase power
output from the drive to the motor.
NOTE
Observe motor polarity, connect phase U on the drive to phase U on
the motor, etc.
For nonstandard motor drive combinations see Appendix D –
Process To Set Up Non-Danaher Motors or consult the factory for
proper phase orientation.