Wiring the Drive 05/2008 Danaher Motion
38 S200-VTS Product Manual
6.2 J1 – AC Input Drive Power
The S200 AC input drives are capable of direct line operation. All units are fully isolated and do
not require external isolation transformers. The inrush current on the connection to the line is
internally limited to a safe level for the drive. There are no voltage selection or ranging switches
required to operate within the specified voltage input ranges.
The S200 series drives are functionally compatible with all standard forms of three phase AC
lines:
Grounded neutral WYE
Open-Delta Grounded Leg
TEE
NOTE
The customer is responsible for supplying the appropriate fuses or
circuit breakers in the J1 AC motor power lines to comply with local
electrical codes.
The control input power required is between 5 and 10 watts. The AC input motor power
depends on output power and losses in the power stage.
CAUTION
Appendix G – Regulatory Information of this manual contains
additional information needed to ensure regulatory compliance.
On AC input drives with peak current < 18 Arms, J1 is a 9 pin pluggable connector (shown
below). On larger AC input drives connections are to fixed terminal block TB1 that needs no
mating connector. See wiring diagrams for full connection details.
Pin Description
J1-1 PE (Protective Earth)
J1-2 REGEN
J1-3 -BUS
J1-4 +BUS
J1-5 C2 CTRL VAC
J1-6 C1 CTRL VAC
J1-7 L3 240 VAC
J1-8 L2 240/120 VAC
J1 Connector view from front of drive.
J1-9 L1 240/120 VAC
Mating Connector Information for S20260, S20250, S20360, S20560, S20660
Screw Terminal Connector
12 – 24 AWG Wire Range, Phoenix MSTB2,5/9-STF-5,08-BK
OR
Spring Cage Clamp Connector
12 – 24 AWG Wire Range, Phoenix FKC 2,5/9-SFT-5,08-BK
OR
Crimp Connector
Crimp Shell
14-20 AWG Wire Range, Phoenix MSTBC 2,5/9-STZF-5,08-BK
Crimp Contact
14-16 AWG Wire Range, Phoenix MSTBC-MT 1,5-2,5
Crimp Contact
18-20 AWG Wire Range, Phoenix MSTBC-MT 0,5-1,0
Refer to
http://www.phoenixcon.com.