Product manual
Quick Start Guides 05/2008 Danaher Motion
26 S200-VTS Product Manual
NOTE for SynqNet: Although the S200 Tools software maintains communication with all
properly connected S200 drives drives on the SynqNet network, only one SynqNet node will be
displayed at a time under the Online display.
4.2.5 SynqNet Configuration
The next step is to set the proper drive and motor feedback configurations.
Under the SynqNet Options tab, select the source for motor feedback (Feedback Source).
Select Base Unit Feedback if the motor feedback is connected to J3 on the S200 Drive.
Select Option Card Feedback if the motor feedback is connected to J14 on the S200 Drive.
4.2.6 Motor Feedback Configuration
The next step is to set the proper motor feedback configurations.
4.2.6.1 SFD
If you are using SFD motor feedback, no further configuration is needed.