Product manual

Danaher Motion 05/2008 Quick Start Guides
S200-VTS Product Manual 23
4.2.3 Hardware Setup
4.2.3.1 Drive Setup
NOTE: The drive serial port (J5) is disabled on SynqNet drives.
If you are using an S200 SynqNet Drive, you need to establish SynqNet communication link
between the S200 SynqNet Drive and the SynqNet motion controller.
Plug one end of an Ethernet communications cable to J11 (SynqNet IN) of the S200 drive and
the other end to the SynqNet controller's OUT port.
One Drive/Node
Use another Ethernet communications cable to connect J12 (SynqNet OUT) of the S200 drive
to the XMP-SynqNet controller's SynqNet IN port.
Multiple Drives/Nodes
Connect an Ethernet communications cable from the XMP-SynqNet controller's OUT port to the
SynqNet IN port (J11) of the first drive/node. Connect an Ethernet cable from the node's
SynqNet OUT port (J12) to the SynqNet IN port (J11) of the next node. Connect another cable
from the SynqNet OUT port (J12) of the last node in the topology to the SynqNet IN port of the
XMP-SynqNet controller.
NOTE: Although you can connect other SynqNet supported nodes/drives on the SynqNet
network, you will only be able to configure the S200 Series Drives with the S200 Tools
software. S200 Tools will only communicate with S200 Series Drives.