Product manual

Danaher Motion 05/2008 Appendix F – Using a Voltage Doubler Mode Drive
S200-VTS Product Manual 127
F.1 S2xx50 AC Line Voltage Doubling Drive Power Specifications
120 VAC Voltage Doubling S20350 S20250
Peak Output Current (ARMS)
0 to 40ºC Ambient
9.0 4.5
Minimum Peak Current Time
Starting from 0 Amps
3.0 3.0
Cont. Output Current (ARMS)
0 to 40ºC Ambient
3.0 1.5
Continuous Output Power (Watts)
750 350
Peak Output Power (Watts)
2400 1200
RMS Line Current at Continuous
Output Power (RMS)
10 5
Fusing – Line Inputs
MDA-15 MDA-10
WARNING
S200 units with the voltage doubling option manufactured before
June 2004 have the function of L1 and L3 reversed. Using 240
VAC on old voltage doubled units with this new documentation
will lead to catastrophic failure of the drive.
Requirements for Safe Operation of the Drive
It is the machine builder’s responsibility.