Product manual
Danaher Motion 05/2008 Regulatory Information
S200-CNS Product Manual 61
12 REGULATORY INFORMATION
12.1 CONFORMANCE REQUIREMENTS
The equipment described herein has been developed, produced, tested and documented in
accordance with the corresponding standards. Use conforming with requirements means that the
safety recommendations and warnings detailed in this manual are complied with and that the
applicable regulations for safety (machine directives, etc.) and noise suppression (EMC Directives)
are observed while operating the drive. At the end of its lifetime, dispose of or recycle the drive
according to the regulations applicable at that time.
12.2 UL AND CUL CONFORMANCE
The S200 drives are UL and cUL Recognized to UL 508C under UL File number E137798. Consider
the following points to ensure that final installation meets UL requirements:
• The drive should be used within its specified ratings.
• The drive should be mounted in the intended manner in an enclosure having adequate strength
and thickness with acceptable spacings for the end product classification.
• The spacings from the exposed live-metal parts to the enclosure wall should be in accordance
with the requirements for the overall equipment.
• These drives shall be used in a pollution degree 2 environment in order to comply with the
spacing requirements of UL 840 and UL 508C.
• The UL temperature tests were done with a metal heat plate with overall dimensions, 6 in x 12 in
x 1/8 in. The machine builder is responsible for ensuring adequate heat sinking capability in the
final installation.
• The thermal protective device(s) provided integral to the motor drives were not evaluated by UL.
• The terminals are suitable for factory wiring only.
• These motor drives have not been evaluated to provide solid-state overload or over speed
protection.
• The DC models were evaluated by UL for use with an isolated power supply rated no more than
150 V open circuit secondary voltage and 10 kVA secondary power. This combination shall be
maintained to satisfy UL requirements.
12.3 CE APPROVAL
The CE initials confirm that the S200 drives satisfy all requirements of CE Directives. However, the
equipment is not ready to operate without additional installations (cable, motor, etc.). Thus, all
necessary tests and measurements had to be made on a typical installation. The test installation
with all peripheral devices, as well as the test results and measurements are recorded in detail in
documentation that is available from the manufacturer on request.
12.4 CE EMC COMPLIANCE
NOTE
If the connection method on your machine is different from the ones pictured in this
manual, or in the event of use of components other than those specified, adherence to
CE interference limit values cannot be guaranteed.
The machine builder should incorporate good EMC installation and wiring practices in
the machine design. Some machine designs require more EMC consideration than
others. For example, a multi-axis machine generates more noise than a single-axis
machine. Therefore, multi-axis machines may require additional noise reduction
techniques, such as a metal enclosure or clamping of cables shields to an RF ground.