Product manual
Danaher Motion 05/2008 Detailed Wiring Information
S200-CNS Product Manual 55
For systems desiring TTL interface, TTL outputs would be tied to A and B while leaving /A and /B
not connected. The DC Commons must be tied together. Open collector interface is shown below.
The above circuit shows a generic interface using open collector drives to drive the encoder input
signals of the S200 PN. Several manufacturers of PLC with step and direction output use this
method. Note the required use of pull up resistors.
5Vdc
225
Ω
x4
6.4k
Ω
x4
100pF x4
5.9k
Ω
x4
J12-12
J12-13
J12-14
J12-15
J12-11
J12-10
S200 Position Node
Inter
nal Equiv Circuits
Field Wiring
Encoder
5Vdc
225
Ω
x4
6.4k
Ω
x4
100pF x4
5.9k
Ω
x4
J12-12
J12-13
J12-14
J12-15
J12-11
J12-10
S200 Position Node
Internal Equiv Circuits
Field Wiring
Controller Step Output
These transistors are
the controller’s Output
(Open Collector
Driver)
Step
Controller Direction Output
E
x
t
R