8.2 J1 – LOW POWER AC INPUT POWER MODELS DRIVE
POWER
Models S202x60-xNS, S203x0-xNS, S206x0-xNS
The S200 AC input drives are capable of direct line operation. All units are fully isolated and do not
require external isolation transformers. The inrush current on the connection to the line is internally
limited to a safe level for the drive. There are no voltage selection or ranging switches required to
operate within the specified voltage input ranges. Please note warnings that follow.
The S200 series drives are functionally compatible with all standard forms of three phase AC lines:
Grounded neutral WYE
Open-Delta Grounded Leg
TEE
19
Figure 7.1: J1 Connector view from front of drive
Pin Description
J1-1 PE (Protective Earth) – Must be tied back to central earth bar.
J1-2 REGEN – Connection for optional external regen resistor.
J1-3 -BUS DC – Internal DC Bus negative connection (Not normally used)
J1-4 +BUS – Internal DC Bus Positive Connection (Regen Resistor
Termination Point)
J1-5 C2 CTRL VAC – Logic control Power can be tied to 120 or 230Vac input
J1-6 C1 CTRL VAC – Logic Control Power can be tied to 120 or 230Vac input
J1-7 L3 240 VAC – Main Line for Bus power: Used for 3
rd
Phase
J1-8 L2 240/120 VAC – Main Line for Bus Power. Used for 1 or 3 Phase
J1-9 L1 240/120 VAC – Main Line. Used for 1 or 3 Phase
Please refer to the Specifications Section for appropriate rating and fusing requirements.
NOTE
It is the customer’s responsibility to supply appropriate fuses or circuit
breakers in the J1 AC drive power lines to comply with local electrical codes.