Installation manual

58
4.7 S200 BASE UNIT FAULTS (B-FAULTS)
As previously stated the base unit Status LED will flash a code if the drive is in
a faulted condition. The following table explains the fault code.
Flash Count
Status Resulting Drive Action Reset Method
1 No Fault drive disabled Normal Operation
2 Motor Over Temp sensor has
tripped
Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
3 Drive Over/Under Temp Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
4 Drive I*t Too High; Exceeded
RMS ratings of the drive.
Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
5 Motor I*I*t Too High; Exceeded
RMS ratings of the motor.
Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
6 Reserved
7 Bus Over Voltage; Mains high-
line or excessive regeneration.
Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
8 Bus Under Voltage Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
9 Motor l-l or l-n Short Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
10 Output Over Current Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
11 Hall Fault Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
12 SFD Configuration Error Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
13 SFD Short Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
14 SFD Motor Data Error Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
15 SFD Sensor Failure Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
16 SFD UART Error Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
17 SFD Comm Error Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
18 Option Card Watch Dog Time
out
Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
19 PosErr Too Large Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
20
Table 4.3: Base Unit Fault Table