Installation manual
50
when using Motion Tasking or Electronic Gearing Modes. Because values of
ACC and DEC are velocity loop parameters low values will appear to cause
instability and severe overshoot when the product is in a position loop control
mode.
3.5 HOMING
Homing is always required. If the application does not require homing then
simply go into the Profile Setup / Homing tab and select ‘Set Current Position
as Home Position’ and ‘Auto Home Move Upon Enabling the Drive’.
3.6 SAVING DRIVE SETTINGS
It is highly recommended that the properly configured drive have its settings
archived on external media for future reconfiguration. Once the drive is
operating properly the data can be uploaded to the host computer. S200 OC
TOOLS User Interface software is used to accomplish this. The drive must be
‘selected’ on the ‘folder-side’ of S200 OC Tools software. Then simply click the
file menus; File / Save (or Save As), name the file as desired, and direct the file
to the desired directory. The file will default with a ‘.CNS’ extension.