Installation manual
36
Sinking Load
For single ended operation, both terminals of the high speed input are available on J4 allowing the input
to be connected to either sinking or sourcing logic. The following shows the connections to drive the high-
speed input from sinking logic.
External
4 - 30 VDC
Power Supply
Sinking Logic Output
from Field Device
External Current Limiting
Resistor for supply > 5.0 V
J4-10
HSINP1+
J4-11
HSINP1-
DC
+
-
Sourcing Load
The following shows the connections to drive the high speed input from sourcing logic. The power supply
can be the same power source used to provide power for the general purpose inputs.
External Current Limiting
Resistor for supply > 5.0 V
External
4 - 30 VDC
Power Supply
Sourcing Logic
Output from Field
Device
J4-11
HSINP1-
J4-10
HSINP1+
DC
+
-