Installation manual
35
DINP5 (and10)
J4-10, 11
General Purpose input default assigned as ‘No Function’. One of two inputs
that can be assigned as end-travel limit switch inputs. Tie pin 10 or 11 to
common rail for normal operation.
J4-10
DINP5+/
HSINP1+
J4-11
DINP5-/
HSINP1-
221 Ω
2.21 k
The high speed input works directly with 5 volt input, 3.0 to 6.0 volt range,
without the use of a current limiting resistor. To operate the input with voltages
higher than 5 volts, an external current limiting resistor is required in series
with the input.
The input current should be in the range of 9 to 24 mA for proper operation.
The following table lists the recommend current limiting resistors for supply
voltages greater than 5 volts.
:))JS$DJH</ :/8HJ,,H,8</,HD
$5 8
!$5 #D&T1
!$5 D&T1