User Guide
Table Of Contents
- Chapter 1: Introduction
- Chapter 2: Theory of the Speech and Music Systems
- Chapter 3: Installation
- Chapter 4: Connecting to a Computer
- Chapter 5: Dugan Control Panel Software
- Chapter 6: Pre-fader Insert
- Chapter 7: Dugan Music System and Gain Limiting
- Chapter 8: Front Panel
- Chapter 9: Updates
Dugan Model M User Guide Connecting to a Computer
23
6. Click Send New Params to Unit.
7. Click Refresh List.
8. Highlight the unit in the list pane again.
If Unit Reachable is YES, this unit is ready to use with the Dugan Control Panel. If
you have additional Dugan units to connect, select the next unit in the list and
repeat Step 4. If you are finished with installation, proceed to Chapter 5: Dugan
Control Panel Software.
If Unit Reachable is NO, proceed to the next step.
9. De-select the Use DHCP parameter.
10.Copy This Computer’s IP Address to the IP Address field, and increase the value in
the last (fourth) group by one.
For example, if This Computer’s IP Address is 192.168.1.101, set IP Address to
192.168.1.102.
11.Click Send New Params to Unit.
12.Click Refresh List.
13.Highlight the unit in the list pane again.
If Unit Reachable is YES, this unit is ready to use with the Dugan Control Panel. If
you have additional Dugan units to connect, select the next unit in the list and
repeat Step 4. If you are finished with installation, proceed to Chapter 5: Dugan
Control Panel Software.
Manually Add Unit
If the Dugan unit does not appear in the Dugan Utility list pane, you can manually
add the unit. First you need to know the IP address of the unit.
To determine the IP address:
1. On the front panel, select MENU by pressing the up and left navigation arrows.
2. Press ENTER.
The MENU screen appears.
3. Select Network Configuration by pressing the up and down navigation arrows.
4. Press ENTER.
The Network Configuration screen appears.
5. Note the IP Address.
To manually add the unit:
1. In the Dugan Utility, click Manually Add Unit.
2. Enter the IP address from the Network Configuration screen.
3. Click OK to exit the dialog.
4. Click Refresh List.