Dan Dugan Sound Design Model K Control Surface User Guide Release Date: March 2016 Version: 1.
Important Safety Instructions and Warnings The Model K’s circuitry is made in the USA and meets applicable national safety standards. Standards Compliance The third-party power supply provided with this product has been certified to comply with UL. Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6.
Warranty Statement Warranty: One year parts and labor Dan Dugan Sound Design warrants that Model K hardware will be free from defects in components and workmanship for a period of 12 months from the date of invoice. During the warranty period, Dan Dugan Sound Design will cover the cost of all parts and labor to remedy the defect, or replace products which prove to be defective.
Dugan Model K Control Surface User Guide Table of Contents Chapter 1: Introduction ............................................................................................. 7 Chapter 2: Installation and Configuration .................................................... 9 Installation .................................................................................................... 9 Best Position..........................................................................................
Dugan Model K Control Surface User Guide 6
Dugan Model K Control Surface User Guide Chapter 1: Introduction The Model K Control Surface provides a physical control surface for any number of Dugan automatic mixing controllers on a local area network. Multiple Model Ks can be used to instantly access more channels, or to let multiple operators run the system. We recommend using the Dugan Control Panel software to set up a system, and the Model K to operate it. It is possible, however, to make most settings from the Model K if desired.
Dugan Model K Control Surface User Guide 8
Dugan Model K Control Surface User Guide Chapter 2: Installation and Configuration Installation The Model K can be conveniently placed on a table top or rack mounted. Best Position Figure 2-1 Model K placed in front of console Rack Mounting We include a rack mounting adapter plate. For table-top use, you can remove the rack adapter plate.
Dugan Model K Control Surface User Guide Power Supply Units include a multi-voltage power supply. In an emergency, the Model K can accept power supplies in the range 12–24 VDC, minimum 1 A. Hardware Connections The Model K provides the following on the rear panel: • Locking power input • Power switch • Ethernet switch with four external ports Figure 2-3 Model K rear panel network and power connectors Make the following hardware connections: 1.
Dugan Model K Control Surface User Guide To set the Model K’s IP address to the factory default: • Press and hold down the left and right arrow buttons together. Release the buttons when lights blink. The unit has been reset to factory defaults including the IP address: 192.168.1.xx, where xx is the last two digits of the unit’s serial number. If the serial number ends with 00, 100 will be used. To manually set the Model K’s IP address on the Model K itself: 1.
Dugan Model K Control Surface User Guide 12
Dugan Model K Control Surface User Guide Chapter 3: Model K Operation This chapter explains how to use the Model K with the Dugan Control Panel software and as a standalone device. Dugan Control Panel Software The Dugan software has both Java and iPad versions. NOTE: After setting up your Dugan automatic mixing controllers, both the Dugan Control Panel and Model K can be disconnected. All settings are retained by the Dugan units, which continue to function on their own.
Dugan Model K Control Surface User Guide Channel Block Selection The left and right arrow buttons (see figure below) select the previous or next block of eight channels in the system. This is just like clicking in the Top Pane of the Dugan Control Panel to select a block. For these actions to mirror each other, pair the Model K with that instance of the Dugan Control Panel (see Pairing the Model K to Dugan Control Panel Software on page 11).
Dugan Model K Control Surface User Guide Channel Knob The knob can be turned and pressed. Its illumination and color changes depending on its function, and the display shows the relevant information. To change settings: 1. Press the knob to cycle through the list of parameters shown in the table below. The parameters vary depending on the Dugan unit being controlled. 2. Turn the knob to set the displayed parameter. Input and Output Level have no settings and appear as a bar graph.
Dugan Model K Control Surface User Guide Table 3-1 Knob Functions Parameter Function Color Level LED (default) Speech Weight NOM only Weight Music Threshold Disabled Bypass Enabled manual auto Ch. Preset mute Disabled Ch. Override Enabled a b Ch.
Dugan Model K Control Surface User Guide Bypass When bypass is active, the signal passes through without automixing. That channel appears inactive, with all lights extinguished except the knob (yellow). If you are using a Dugan unit with analog I/O, bypass mode physically connects the input to the output with a relay. Channels are automatically bypassed when the power is off. In man mode, the signal undergoes an A/D and D/A conversion, with the specified latency, but no automixing.
Dugan Model K Control Surface User Guide Method to Use During Show 1. Press the channel knob repeatedly until Ch. Preset appears in its display. 2. Turn the knob until the desired mode (man, auto, mute) appears in its display. An LED lights next to the button for that mode. 3. Press the knob twice quickly to return to the default display. NOTE: See page 21 for instructions on how to use the preset function. Override To mute all mics except one for the host or chairperson, use the override function.
Dugan Model K Control Surface User Guide Group Assignment Groups are separate automatic mixers. Every channel is in a group (a, b, c); group a is the default. Channels can be assigned to groups using the channel knob (described above), or the following shortcut method. Shortcut 1. In the Master section, press and hold the group’s knob. All knobs light in the colors for their assigned groups. 2. For each channel you wish to include in this group, press the channel’s knob.
Dugan Model K Control Surface User Guide New Scene To create a new Scene from the Model K: • Press and hold the bright knob, then press the + button. A Scene number is assigned and appears in the display. The Scene can be renamed in the Dugan Control Panel software. Recall Scene To recall a saved Scene: 1. Press the + or - buttons to scroll through the available Scenes, which are displayed in the window above. 2. Press enter to recall the currently displayed Scene.
Dugan Model K Control Surface User Guide Master Section The Master Section contains a knob and three buttons for each group (a, b, c). Group Master Buttons Override Pressing the Master over button puts the group into override mode and has the following effect on individual channels: • Channel override LED active: puts the channel in man mode with full gain (no automixing); - OR - • Channel override LED inactive: mutes the channel. The over button winks while override mode is active.
Dugan Model K Control Surface User Guide Group Master Knobs These knobs illuminate to show that there are inputs assigned to the group. If all inputs in a group are assigned to the Speech System, the knob lights green. If any input in a group has NOM on or is assigned to the Music System, the knob lights white. When the knob is lit white, the Music System parameters for that group can be set as follows: 1. Turn the knob to set the Music System Threshold Input gain.
Dugan Model K Control Surface User Guide Brightness Knob and Master Display The Master display is located above the right arrow. By default it shows the name and model of the selected Dugan controller. • Turn the bright knob to set the overall brightness. • Press the bright knob repeatedly to access the parameters in the table below. • From any parameter, press the bright knob twice quickly to return to the default display.
Dugan Model K Control Surface User Guide 24
Dugan Model K Control Surface User Guide Chapter 4: Model K Specifications Connectors Power Network Coaxial with locking collar, 5.5 mm o.d., 2 mm i.d. 4 x RJ-45: Four-port internal switch for network Power Electrical External Supply Nominal 12 VDC, 1 A maximum; accepts 12–24 VDC; center pin positive Input: 100–240 VAC, 50–60 Hz, 0.7 A Output: 18 VDC, 1.33 A Approved UL, GS, CE, FCC, CCC, LPS Physical Dimensions Weight H = 4.2 in (106 mm) D = 3.2 in (81 mm) W = 17.
Dugan Model K Control Surface User Guide 26