Operation Manual

22
* pump sucks false air - check all pipes at the suction-
side on leakage.
* too little water in the - increase the watersupply.
floatation tank
* dosaging cock is open and - fill soaptank (fig. 4;169) or
no soapsupply close dosaging cock (fig. 1;163).
* safety valve leaks or is - adjust safety valve (fig. 3;188)
tuned up too low or repair leakage.
* leakage at pressure side - check tube coil, pipes, hoses and coup-
of the pump lings on leakage and repair or
replace if necessary.
* defective pump - consult service.
5 No soapsupply:
* suction hose clogged - clean hose
* suction hose is hanging - immerse, if necessary refill
above the soap level the soaptank.
6 Burner gives too much smoke:
* bad fuel - clean tank and fill again with
good fuel.
* oilpump sucks false air - check suction pipe on leakage.
* insufficient burning - consult service.
8.0 TECHNICAL DETAILS
Type HWO 1000
ordernumber 66603
dimensions (lxwxh) 1055 x 745 x 765 mm
weight ca. 175 kg
driving motor 4 kW (5,5 Hp), 380 V, 50 Hz
lead 5 mtr, 4 x 2,5 qmm
fuse 20 A (slow)
voltage 220/380 V rotating current
burnermotor 130 W
burner capacity 235.000 kJ/h
fuel diesel oil/domestic fuel oil
fuel tank 25 ltr
temperature adjustable to 95
o
C
high pressure waterpump Speck plungerpump model NP16/15-210
waterconsumption up to 1000 ltr/h
waterpressure adjustable to 150 bar
detergent tank internal 20 ltr
detergent sucking can be dosed phaseless from 2 sucking
possibilities