1.2.6.1 System Connector
Use a LSA tool for the Ethernet connection
Figure 1-19: System Connector
Connect the following terminals:
NOTE: Cable used must be 0.4mm
2
to 0.6mm
2
(24AWG) solid cores
Function SB421 Function BS421 Color
ETH_IN 8 ETH_OUT 1 White / Orange
ETH_IN 7 ETH_OUT 2 Orange
ETH_OUT 6 ETH_IN 3 White / Green
ETH_OUT 5 ETH_IN 4 Green
SEC_IN 4 SEC_OUT 5 Blue
SEC_IN 3 SEC_OUT 6 White / Blue
SEC_OUT 2 SEC_IN 7 White / Brown
SEC_OUT 1 SEC_IN 8 Brown
POWER:
NOTE: Cable used must be equal to or more than 3 x 1,5mm
2
(e.g. DAMM no. 883013)
Ground GND 1 Yellow/Green
0 + 2 Black
-48Volt - 3 Blue