User's Manual

Doc. No.
Rev.
Date
DRAFT
1.01
2012-01-27
Damm Cellular Systems A/S, Denmark
TetraFlex
®
7.5 Manual - BS41x
TetraFlex® 7.5
Manual
1-25
1.3.4 Attaching antennas
Before installing the Base Station please read the application note in this manual about the
Antenna Systems.
The following antenna cables shall be attached:
If the jumper between ANTA and RSOUT is NOT connected (Separate RXA, RXB and TX
antennas)
o 3 cables to the TMD412 (two RXA and RXB and one for Test)
o 1 cable to the TX antenna
o 1 or 2 cables to the GPS antennas
When a jumper coaxial wire is connected between ANTA and RXOUT on the TMD.
o 3 cables to the TMD412 (one RXA/TX, one RXB and one for Test)
o 1 or 2 cables to the GPS antennas
Figure 1-22: Antenna connectors
1.3.5 Connection to Battery
Before starting on this point please read the section 1.3.8.3 in this manual about Battery
attachment.
The BS may be connected to a 48V battery, which the BS can charge.
The Base Station is prepared for 60V battery operation, wherefore a switch is placed on the
back plane of the BS to indicate to the PS411’s, whether a –48V or 60V battery is used.
Note that the present version of PS411 can only operate with 48V DC, wherefore this
feature is not active, and the switch shall be placed in the 48V position.
The Switch is accessible by removing the PS411 Power Supplies.