Specification Sheet

FLOOR
MARBLE ATTACHÉ
COLORBODY
PORCELAIN with REVEAL IMAGING
®
7834 C. F. Hawn Freeway,
Dallas, Texas 75217 | 1.800.933.TILE
To view the complete collection of
Daltile
®
products and information,
visit our website at daltile.com.
DESIGNED TO HELP EARN LEED™
CREDITS. For more detailed information,
visit daltilegreenworks.com. ©2016 Dal-Tile Corporation (8/16)
SCAN QR CODE
FOR PRODUCT
INFORMATION
Get a QR Code
reader at:
GET.DALTILE.COM
Generated by BeQRious.com
SIZES
Thickness
Sq. Ft.
per Carton
Pieces per
Carton
24 x 48
Field Tile n
(23-3/8" x 46-7/8")
(59.44 cm x 119.20 cm)
3/8" 15.24 2
24 x 24
Field Tile n
(23-3/8" x 23-3/8")
(59.44 cm x 59.44 cm)
3/8" 15.20 4
12 x 48
Field Tile n
(11-5/8" x 46-7/8")
(29.56 cm x 119.20 cm)
3/8" 11.37 3
12 x 24
Field Tile n
(11-5/8" x 23-3/8")
(29.56 cm x 59.44 cm)
3/8" 15.12 8
2 x 2 Mosaic u
(Mesh-mounted
on 12" x 12" Sheet)
(11-3/4" x 11-3/4" Sheet)
(29.85 cm x 29.85 cm Sheet)
3/8" 9.60 10
2 x 5 Linear
Hex Mosaic u
(Mesh-mounted
on 12" x 12" Sheet)
(12-7/16" x 12-11/16" Sheet)
(31.60 cm x 32.23 cm Sheet)
3/8" 11.00 10
n Available in Matte, Satin and Polished finishes. Matte available Fall 2016.
u Matte finish only
INSTALLATION
Grout Joint Recommendation Shade Variation
1/8" (3/16" when multiple sizes are
installed in a modular pattern and/or
when tile with a length 15" or greater
is installed in a staggered brick-joint
pattern. Overlap should not exceed 33%)
Random (V4)
TEST RESULTS
ASTM#
Satin &
Polished
Result
Matte
Result
Water Absorption C373 < 0.5% < 0.5%
Breaking Strength C648 > 275 lbs > 275 lbs
Scratch Hardness MOHS 7.0 8.0
Chemical Resistance C650 Resistant Resistant
NOTES
Manufacturer Advisory (Satin and Polished only): These tiles have
a dynamic coefficient of friction < 0.42 as measured by the DCOF
Acutest method. Tiles with DCOF values < 0.42 are not recommended
for use in areas with wet or slippery conditions. For more information,
see ANSI standard A137.1 section 6.2.2.1.10, available at
www.tileusa.com.
Special consideration needs to be given when installing tiles greater
than 15 inches. Please refer to daltile.com/LargeTiles for more
information.
Strong random shading enhances the natural beauty of this product.
To achieve optimal results, tile should be selected from multiple
cartons and shading arrangement planned prior to installation.
Special care should be taken when grouting with dark pigmented
colors. A grout release is recommended to prevent finely powdered
pigments from lodging in the pores of the surface. Use of a latex
modified thin-set is recommended for installation.
Since there are variations in all fired ceramic products, tile and
trim supplied for your particular installation may not match these
samples. Final color selection should be made from actual tiles and
trim and not from tile samples or color reproductions. Manufactured
in accordance with ANSI A137.1 standards.
Water, oil, grease, etc. create slippery conditions. Floor applications
with exposure to these conditions require extra caution in product
selection. Not for use on ramps.
For additional information refer to “Factors to Consider” at
daltile.com/Factors.
FLOOR APPLICATIONS
Target
DCOF wet
Suitable
Dry & Level – Interior N/A
Wet & Level – Interior ≥ 0.42 *
Exterior Applications;
Pool Decking & Other Wet Areas
with Minimal Footwear
≥ 0.60
Ramps & Inclines ≥ 0.65
A DCOF value of ≥ 0.42 is the standard for tiles specified for level interior spaces
expected to be walked upon when wet, as stated in ANSI A137.1-2012, Section 9.6. For
more information about DCOF and the DCOF AcuTest
, visit daltile.com/DCOF.
OTHER APPLICATIONS
Suitable
Walls/Backsplashes
Countertops
Pool Linings **
APPLICATION NOTES:
* Matte finish only
** Mosaics only
Suitable for exterior applications in freezing and non-freezing climates when proper
installation methods are followed.
Satin and polished surfaces are suitable only for dry and level floor applications.
TRIM
Type Number Size
Pieces per
Carton
Bullnose n S-43F9 3 x 24 10
Bullnose trim intended to coordinate with floor field tile in the
standard 90-degree installation position.