User`s manual
4M30 Camera User’s Manual 16
DALSA 03-32-10030-03
Figure 6: Trigger Timing Description
2.8 Integration Time
The minimum integration time (or shutter time) is 10 Ps. As with any full frame imager,
the camera will continue to integrate during read out unless externally shuttered or
strobed.
2.9 Timing
The 4M30 pixel clock runs at 40 MHz, so each pixel clock cycle will be 1/40,000,000 or 25ns.
The following diagram and tables describe the correct timing requirements for the 4M30
camera.
Figure 7: 4M30 Timing
VSYNC
Data
HSYNC
PIXEL
CLOCK
1
23
A
B C
C
E
D
F