Specifications
405-00022-00VA6x User’s Reference
24 Rev 00; 16 October 2007
Power Connector
The VA61 is powered from an external supply (option A-PWR-NSII) that connects to the 3-pin
male D-Sub connector on the back panel. The power requirements are:
+24 V +/–10% @ 2.5 A maximum.
Pin 1
Figure 14. Power Connector
I/O Connector Pinout
Pin Name Direction Description
1 GND – Ground
2 +24V Input DC Power
3 NC – not connected
A power cable (A-CAB-NSII-PWR), with open leads on one end and a mating connector plug on