Specifications
VA6x User’s Reference405-00022-00
11Rev 00; 16 October 2007
Cable Pin-Out
Camera 12-Pin Hirose Description Direction VA61 15-Pin DB15
1 Power Ground 10
2 +12 Volt Power 15
3 OUT 1 – 7 (no connnection on VA61)
4 OUT 1 + Camera Output 13 (no connnection on VA61)
5 IN 1 – 8 (no connnection on VA61)
6 IN 1 + Camera Input 14 (no connnection on VA61)
7 Out 2+ / Strobe Camera Output 12
8 Out 2 – 6
9, 10 No Connection 1,2,3,5,11
11 IN 2 + / Trigger Camera Input 9
12 IN 2 – 4
15 pins12 pins
see below
Figure 3. Control and Power Cable
Part Number
Cable Length
A-CAB-GTP-00
3 meters
A-CAB-GTP-01
5 meters
A-CAB-GTP-02
10 meters
Another possible configuration would be:
• The camera is triggered directly from the part sensor, bypassing the VA61.
• The camera’s strobe output is connected directly to the lighting equipment, bypassing the
VA61.
For this case, DALSA offers an optional DCI-100 DALSA Camera Interface module for con-
necting the camera signals to terminal block connectors. The same Control and Power cable is
used to connect the Cameras to the DCI-100. The Camera Connectors on the VA61 would not be
used for the strobe and trigger signals when the DCI-100 is in use.