User`s manual
Falcon 4M Camera Manual
DALSA 03-032-20044-01
73
Revised Falcon 4M30 and 4M60 User Timing (-01-R and higher cameras)
Operating Conditions SEM
EDC
CLM
SOT
SSF 2
frame rate - ext controlled 4,6
SET 2
SET 6
EFD
012012012012
Exposure Timing
A User Exsync ↑ to Internal Exsync ↑ 4 149n 249n 485u 149n 249n 559u 149n 249n 485u 149n 249n 594u
B4 User Exsync ↓ to Internal Exsync ↓ 4 186n 486u 311n 186n 560u 311n 186n 486u 311n 186n 594u 311n
B6 User Exsync ↓ to Internal Exsync ↑ 6 237n 337n 484u 237n 337n 558u 237n 337n 484u 237n 337n 594u
C Internal Exsync ↑ to Exposure ↑ 2,4,6 1.40u 1.40u 1.40u 1.40u
D Internal Exsync ↓ to Exposure ↓ 2,4,6
E Exposure ↓ to FVAL ↑ 2,4,6
LVAL / FVAL Timing
F4 User Exsync ↓ to FVAL ↑ 4 84u 570u 84u 140u 700u 140u 84u 570u 84u 167u 762u 167u
F6 User Exsync ↓ to FVAL ↑ 6 2.56m 2.70m 2.56m 2.75m
tFL, G FVAL ↑ to LVAL ↑ 2,4,6
tLVAL_LOW1, H1 LVAL ↓ to LVAL ↑ (LVAL low 1) 2,4,6
tLVAL_LOW2, H2 LVAL ↓ to LVAL ↑ (LVAL low 2) 2,4,6
tLF, J LVAL ↓ to FVAL ↓ 2,4,6
tLINE, K LVAL ↑ to LVAL ↓ 2,4,6
tREADOUT, L FVAL ↑ to FVAL ↓ 2,4,6
Max Frame Rate Timing
SSF (max FR) 2 62.2Hz 60.4Hz 60.3Hz 31.1Hz 30.6Hz 30.6Hz 62.2Hz 60.4Hz 60.3Hz 25.2Hz 24.9Hz 24.9Hz
Max Exposure 2 16051u 16530u 52u 32109u 32635u 32u 16051u 16530u 52u 39629u 40107u 31u
twSYNC Internal Exsync ↓ to Internal Exsync ↑ 2 16.6m 32.6m 16.6m 40.2m
twSYNC_INT Internal Exsync ↑ to Internal Exsync ↓ (min) 2 10u 492u 10u 10u 566u 10u 10u 492u 10u 10u 601u 10u
tTRANSFER Internal Exsync ↓ to FVAL ↑ 2
tOVERHEAD FVAL ↓ to Internal Exsync
↓ (max FR) 2 2.05u 482u 510u 21.8u 548u 548u -1.4u 478u 506u 94.4u 574u 574u
tFRAME PERIOD Internal Exsync ↓ to Internal Exsync ↓ 2 16.08m 16.56m 16.58m 32.16m 32.69m 32.69m 16.07m 16.55m 16.58m 39.68m 40.16m 40.16m
84.2u 140u 84.2u 167u
130
23.7
5
2000 566 2000 601
260
50 28.8 50
29.2u 47.8u 29.2u 56.4u
15.99m 32.00m 15.99m 39.42m
7.35u 14.7u 9.04u 18.1u
2.08m 2.16m
0
0
100n 123n
3.70u 7.52u 292n 9.32u
320 160
2.07m 2.13m
0
163163
3.11u
80.9u 136u 80.8u 164u
109n 109n 109n 109n
2000 686 2000 2000
Notes:
* Units in seconds.
* Additional operating conditions: full window readout, snd 1.
* User EXSYNC operates asynchronous to the camera timing and therefore has an uncertainty period of +/-2 clocks (80 MHz clock
= 12.5 nS, 2 clocks = ± 25 nS).
* When the debounce circuit is enabled (
edc 1) increase timing values A, B4, B6, F4 and F6 by 1.07 uS.