User`s manual
Falcon 4M Camera Manual
03-032-20044-01 DALSA
72
Original Falcon 4M30 and 4M60 User Timing (-00-R and non-RoHS cameras)
Operating Conditions SEM
EDC
CLM
SOT
SSF 2
frame rate - ext controlled 4,6
SET 2
SET 6
EFD
012012012012
Exposure Timing
A User Exsync ↑ to Internal Exsync ↑ 4 85n 186n 485u 85n 186n 559u 85n 186n 502u 85n 186n 594u
B4 User Exsync ↓ to Internal Exsync ↓ 4 123n 486u 247n 123n 560u 247n 123n 504u 247n 123n 594u 247n
B6 User Exsync ↓ to Internal Exsync ↑ 6 123n 286n 484u 123n 286n 558u 123n 286n 502u 123n 286n 594u
C Internal Exsync ↑ to Exposure ↑ 2,4,6 1.40u 1.40u 1.40u 1.40u
D Internal Exsync ↓ to Exposure ↓ 2,4,6
E Exposure ↓ to FVAL ↑ 2,4,6
LVAL / FVAL Timing
F4 User Exsync ↓ to FVAL ↑ 4 60.2u 546u 60.2u 60.2u 546u 60.2u 73.4u 578u 73.4u 142u 736u 142u
F6 User Exsync ↓ to FVAL ↑ 6 2.54m 2.67m 2.55m 2.73m
tFL, G FVAL ↑ to LVAL ↑ 2,4,6
tLVAL_LOW1, H1 LVAL ↓ to LVAL ↑ (LVAL low 1) 2,4,6
tLVAL_LOW2, H2 LVAL ↓ to LVAL ↑ (LVAL low 2) 2,4,6
tLF, J LVAL ↓ to FVAL ↓ 2,4,6
tLINE, K LVAL ↑ to LVAL ↓ 2,4,6
tREADOUT, L FVAL ↑ to FVAL ↓ 2,4,6
Max Frame Rate Timing
SSF (max FR) 2 62.2Hz 60.4Hz 60.3Hz 31.1Hz 30.6Hz 30.6Hz 50.3Hz 49Hz 49Hz 25.2Hz 24.9Hz 24.9Hz
Max Exposure 2 16051u 16530u 52u 32109u 32635u 32u 19850u 20377u 49u 39629u 40107u 31u
twSYNC Internal Exsync ↓ to Internal Exsync ↑ 2 16.6m 32.6m 20.4m 40.2m
twSYNC_INT Internal Exsync ↑ to Internal Exsync ↓ (min) 2 10u 492u 10u 10u 566u 10u 10u 510u 10u 10u 601u 10u
tTRANSFER Internal Exsync ↓ to FVAL ↑ 2
tOVERHEAD FVAL ↓ to Internal Exsync ↓ (max FR) 2 24.2u 504u 532u 42.2u 568u 568u 13.5u 542u 542u 115u 594u 594u
tFRAME PERIOD Internal Exsync ↓ to Internal Exsync ↓ 2 16.07m 16.55m 16.58m 32.16m 32.68m 32.68m 19.89m 20.42m 20.42m 39.68m 40.16m 40.16m
0
0
1.87u 3.78u 2.30u 4.66u
1.94u 3.82u 2.50u 4.76u
2.06m 2.10m 2.06m 2.14m
3.11u
57.0u 112u 70.2u 138u
2000 686 2000 2000
5
2000 566 2000 601
50 28.8 50 23.7
320 160 260 130
112n 112n 112n 112n
0
163163
7.35u 14.7u 9.04u 18.1u
15.99m 32.00m 19.8m 39.42m
29.2u 47.8u 33.7u 56.4u
60.2u 116u 73.4u 142u
Notes:
* Units in seconds.
* Additional operating conditions: full window readout, snd 1.
* User EXSYNC operates asynchronous to the camera timing and therefore has an uncertainty period of +/-2 clocks (80 MHz clock
= 12.5 nS, 2 clocks = ± 25 nS).
* When the debounce circuit is enabled (
edc 1) increase timing values A, B4, B6, F4 and F6 by 1.07 uS.