User`s manual
Falcon 4M Camera Manual
DALSA 03-032-20044-01
17
Camera Link Connector Pinout
Medium Configuration Base Configuration
Up to an additional 2 Channel Link Chips One Channel Link Chip + Camera
Control + Serial Communication
Camera
Connector
Right Angle
Frame Grabber
Connector
Channel Link
Signal
Camera
Connector
Right Angle
Frame
Grabber
Connector
Channel
Link Signal
1 1 inner shield 1 1 inner shield
14 14 inner shield 14 14 inner shield
2 25 Y0- 2 25 X0-
15 12 Y0+ 15 12 X0+
3 24 Y1- 3 24 X1-
16 11 Y1+ 16 11 X1+
4 23 Y2- 4 23 X2-
17 10 Y2+ 17 10 X2+
5 22 Yclk- 5 22 Xclk-
18 9 Yclk+ 18 9 Xclk+
6 21 Y3- 6 21 X3-
19 8 Y3+ 19 8 X3+
7 20 100 ohm 7 20 SerTC+
20 7 terminated 20 7 SerTC-
8 19 Z0- 8 19 SerTFG-
21 6 Z0+ 21 6 SerTFG+
9 18 Z1- 9 18 CC1-
22 5 Z1+ 22 5 CC1+
10 17 Z2- 10 17 CC2+
23 4 Z2+ 23 4 CC2-
11 16 Zclk- 11 16 CC3-
24 3 Zclk+ 24 3 CC3+
12 15 Z3- 12 15 CC4+
25 2 Z3+ 25 2 CC4-
13 13 inner shield 13 13 inner shield
26 26 inner shield 26 26 inner shield
Notes:
*Exterior Overshield is connected to the shells of the connectors on both ends.
**3M part 14X26-SZLB-XXX-0LC is a complete cable assembly, including connectors.
Unused pairs should be terminated in 100 ohms at both ends of the cable.
Inner shield is connected to signal ground inside camera
DALSA Camera Control Configuration
Signal Configuration
CC1 EXSYNC
CC2 Reserved for future use
CC3 Reserved for future use
CC4 Window toggle