User`s manual

4M Stop Action Camera Manual PRELIMINARY
59
ling and
Appendix B
Error Hand
Command List
B1 All Available Commands
ands available to the camera
user. For detailed information on us er 3.
l A le Co ands
As a quick reference, the following table lists all of the comm
ing these commands, refer to Chapt
Table 16: Al vailab mm
correction calibrate
FPN
ccf
Performs FPN calibration and
eliminates FPN noise by subtracting
away individual pixel dark current.
camera link mode
clm m
Output mode to use:
2: Base configuration, 2 taps, 8 bit
output
3: Base configuration, 2 taps, 10 bit
output
15: Medium configuration, 4 taps, 8 bit
output (4M60 only)
16: Medium configuration, 4 taps, 10
bit output (4M60 only)
calculate PRNU
algorithm
cpa i i
Performs PRNU calibration according
to the selected algorithm.
The first parameter is the algorithm
where i is:
2 = Calculates the PRNU coefficients
using the entered target value
PRNUCoefficient=
Target
(AVG PixelValue)‐(FPN+value)
sdo
i
i
i
This algorithm is useful for achieving
uniform output across multiple
cameras.
DALSA 03-32-10121-09