User`s manual
Spyder3 GigE Vision SG-14 Monochrome Cameras User’s Manual    81 
Teledyne DALSA    03-032-20123-01 
Current Counter Value 
Displays the current counter value 
Input Debouncing 
The Debouncers tab is used to configure the debouncers of the camera. The debouncers are associated 
with the first and second PHYSICAL inputs of the software, usually Input 1 and Input 2. 
The debouncers make sure that their corresponding inputs filter out bouncing effects. Bouncing is when 
there are a few very short pulses when the input signal transitions from low to high. Without 
debouncing, the controller may see these small pulses as real signals. 
The debouncers make sure that the signal is truly high for the specified amount of time befor e it is 
declared as high. The same applies to the falling edge. 
Input 0 Value 
Indicates the debouncing value for input 0. Each unit is equal to 16 clock cycles (30ns each), or 480ns. 
Input 1 Value 
Indicates the debouncing value for input 1. Each unit is equal to 16 clock cycles (30ns each), or 480ns. 
Input 2 Value 
Indicates the debouncing value for input 2. Each unit is equal to 16 clock cycles (30ns each), or 480ns.  
Input 3 Value 
Indicates the debouncing value for input 3. Each unit is equal to 16 clock cycles (30ns each), or 480ns. 