User`s manual

78 Spyder3 GigE Vision SG-14 Monochrome Cameras User’s Manual
03-032-20123-01 Teledyne DALSA
I6, for pulse generator 1
Rescaler
The Rescaler lets you change the frequency of a periodic input signal. You can use the Rescaler to
multiply the period by up to 4096 or divide it by up to 4095.
Figure 61: Granularity
The Rescaler is defined by the following settings:
Granularity
The granularity is the number of clock cycles during which the rescaler checks for activity on its input.
The value to use depends on the period/ frequency of the input signal. If a frequency lies between two
different granularity settings, the lowest setting will yield a better precision. The possible values are:
Acceptable Line rate relative to Granularity
Gran
Precision
Minimum
Period
Maximum Period
Min.
Frequency
Max. Freq.
(ER<1%)
(30 ns)
(s)
(s)
(Hz)
(Hz)
0
1
0.00000006
0.00197
509
333,333
1
4
0.00000024
0.00786
127
83,333
2
16
0.00000096
0.03146
32
20,833
3
256
0.00001536
0.50332
2.0
1,302
TheMin. Frequency is a fixed minimum, otherwise the incoming signal period counter gets
saturated (reach the maximum count).
TheMax. Freq. is a recommended maximum to get Error less than 1%.
Multiplicator
The multiplier applied to the input frequency. The possible values are:
Frequency is multiplied by 256 (PLC_rsI0_Multiplier = FrequencyX256)
Frequency is multiplied by 16 (PLC_rsI0_Multiplier = FrequencyX16)
Frequency is multiplied by 4096 (PLC_rsI0_Multiplier = FrequencyX4096)