User`s manual

Spyder3 S3-14 and S3-24 User's Manual 9
Teledyne DALSA 03-032-20117-00
Electrical Interface
1k and 2k
4k
Input Voltage
+ 12 to +15 Volts DC
Power Dissipation
< 5 W (1k and 2k)
< 7 W (4k)
Operating Temperature
0 ºC to 65 ºC
Bit Width
8 or 12 bits user selectable
Output Data Configuration
Base Camera Link
*Lens mount adapters are available. Contact Teledyne DALSA Sales for more information.
Table 3: Camera Operating Specifications
Specifications
Unit
-10dB
0dB
+10dB
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
Broadband
responsivity
DN /
(nJ/cm²)
1k and 2k Dual line
652.8
2064
6528
1k and 2k Single line
326.4
992
3264
4k Dual line
431
1363
4310
4k Single line
216
682
2155
Random noise rms
DN
3
6.5
9.2
20.5
30
65
Dynamic range
DN : DN
1k and 2k Dual line
500:1
1400:1
203:1
324:1
59:1
108:1
1k and 2k Single line
500:1
1400:1
203:1
324:1
59:1
108:1
4k Dual and Single
1225:1
387:1
122.3:1
FPN global
DN p-p
Uncorrected
52.8
169.6
536
Corrected
32
32
64
PRNU ECD
Uncorrected local
%
8.5
8.5
11.5
Uncorrected global
%
10
10
10
Corrected local
DN p-p
80
80
95
Corrected global
DN p-p
80
80
95
PRNU ECE
Uncorrected local
%
8.5
12
37
Uncorrected global
%
10
12
37
Corrected local
DN p-p
80
237
752
Corrected global
DN p-p
80
208
752
SEE (calculated)
nJ / cm²
Dual line
6.35
1.92
0.61
Single line
12.2
4.0
1.2
NEE (calculated)
pJ / cm²
Dual line
4.6
4.5
4.6
Single line
9.2
9.3
9.2
Saturation output
amplitude
DN
3968
±80
DC offset
DN
96
160
336