User`s manual
88 Spyder3 S3-14 and S3-24 User's Manual
03-032-20117-00 Teledyne DALSA
Camera Interface Parameters (PRELIMINARY)
Table 21: Frame Grabber Interface Parameters
Item (when
programmable
configuration the
options are
separated with a | )
S3-14-01k40
S3-24-01k40
S3-14-02k40
S3-24-02k40
S3-24-04k-40
Imager Dimension <1,2
or 1| 2>
1
1
1
1
1
Imager
Columns<number of
active columns, X>
1024
1024
2048
2048
4096
Imager Rows<number of
active rows, Y> Line
Scan/ TDI are defined as
1
1
1
1
1
1
Number of CCD Taps
<1,2,3…..>
1
2
1
2
2
Sensor Tap Clock Rate
<xx MHz>
40
40
40
40
40
Camera Standard
<NTSC, PAL, VS, VW,
MW>
VS
VS
VS
VS
VS
Variable Window
<Column Start, Column
End, Row Start, Row
End>
(0,0,0,0)
All zeros
indicates an
unsupported
feature
(0,0,0,0)
All zeros
indicates an
unsupported
feature
(0,0,0,0)
All zeros
indicates an
unsupported
feature
(0,0,0,0)
All zeros
indicates an
unsupported
feature
(0,0,0,0)
All zeros
indicates an
unsupported
feature
Multiple Window
Number of Windows
(Column Start 1, Column
End 1, Row Start 1, Row
End 1) (Column Start 2,
Column End 2,...)
0, (0,0,0,0)
All zeros
indicates an
unsupported
feature
0, (0,0,0,0)
All zeros
indicates an
unsupported
feature
0, (0,0,0,0)
All zeros
indicates an
unsupported
feature
0, (0,0,0,0)
All zeros
indicates an
unsupported
feature
0, (0,0,0,0)
All zeros
indicates an
unsupported
feature
Number of Camera
Configurations<1,2,3,…>
2
2
2
2
2