User`s manual

Spyder3 S3-14 and S3-24 User's Manual 75
Teledyne DALSA 03-032-20117-00
Mnemonic
Syntax
Parameters
Description
set subtract background
ssb
t i
Subtract the input value from the output signal.
t = Tap value. 0 for all taps or 1 to number of camera taps
for individual tap selection.
i = Subtracted value in a range from 0 to 4095.
set sync frequency
ssf
i
Set the frame rate to a value from 300Hz to 36000Hz
(2k model) or 300Hz to 68000Hz (1k model). Value
rounded up/ down as required.
set system gain
ssg
t i
Set the digital gain.
t = tap selection, either 1 to 2, or 0 for all taps
i = Digital gain in a range from 0 to 65535. The digital
video values are m ultiplied by this number.
set sensitivity mode
ssm
i
Sets the cam era’s sensitivity m od e w here i is:
0 = Low sensitivity mode
1 = High sensitivity mode
2 = Tall pixel mode
set upper threshold
sut
i
The pixels equal to or greater than the upper threshold
are checked for and reported in the end -of-line sequence
in a range from 0-4095.
set video mode
svm
i
Switch between normal video mode and camera test
patterns:
0: Normal video mode
1: Camera test pattern
2: Camera test pattern
update gain reference
ugr
Changes 0dB gain to equal the current analog gain value
set with the sag command.
verify temperature
vt
Check the internal temperature of the camera
verify voltage
vv
Check the camera’s inp ut voltages and return OK or fail
write FPN coefficients
wfc
i
Write all current FPN coefficients to non-volatile
memory, where i is:
1 = FPN coefficient set one
2 = FPN coefficient set two
3 = FPN coefficient set three
4 = FPN coefficient set four
write input LUT
wil
i
Write current LUT’s to non -volatile memory.
i=1 to 4
write PRNU coeffs
wpc
i
Write all current PRNU coefficients to non-volatile
memory, where i is:
1 = PRNU coefficient set one
2 = PRNU coefficient set two
3 = PRNU coefficient set three
4 = PRNU coefficient set four
write user settings
wus
Write all of the user settings to non-volatile memory.