Loading a Saved Set of Coefficients
The lpc command Loads one of the 4 saved sets of pixel coefficients. In addition, a factory calibrated set of
coefficients is available.
Camera Link Command
Parameter
Description
Notes
lpc i
FPN coefficients set to save.
0 = Factory calibrated pixel
coefficients.
1 = Coefficient set one
2 = Coefficient set two
3 = Coefficient set three
4 = Coefficient set four
Example
lpc 0
Resetting the Current Pixel Coefficients
The rpc command resets the current pixel coefficients to zero. This command does not reset saved
coefficients.
Camera Link Command
Parameter
Description
Notes
rpc
The digital offset is not reset.
Example
Rebooting the Camera
The command rc reboots the camera. The camera starts up with the last saved settings and the baud rate
used before the reboot order. Previously saved pixel coefficients are also restored.